200 kW Natural Gas Generator Set

Integrated Power Systems International, Inc.

Generator Set Rating
Three Phase             60 Hz               50 Hz
                                   kW/KVA        kW/KVA

Continuous
Standby 150°C         200/250            168/210
Prime Power 105°C  190/238            152/190

Single Phase       
   60 Hz              50 Hz
                                   kW/KVA       kW/KVA
Continuous
Standby 150°C         127/127           127/127
Prime Power 105°C  107/107           141/141
Quality Power Producing Equipment
is our business at Integrated Power Systems International Inc. Our power systems offer solutions to requirements for reliable, Quality electrical power.
* 100% full load tested.
* Performance supported by prototype testing.
* 12 lead re-connectable AC synchronous generators.
* Solid state automatic voltage regulator.
* 50 or 60 Hz operational.
* Standard Digital Control Panel meeting standards set by NFPA-110.
200 kW Natural Gas Generator Set
Product Features

System Reliability and Longevity
begin with design experience and integrity.

Single Source Responsibility:
Product services support and parts available through IPSI.

Accessories and Flexibility
are designed into IPSI generator sets at the factory level to meet specific application needs.

Organizational Commitment
to innovative, leading edge technology and environmentally friendly electrical products and services.



Technical Specifications

200 kW NG Generator Set
IPSI - Power On Wheels  

Engine Specifications
Manufacturer
Model
Type 4 cycle, In line
Aspiration

Turbo/ After cooled

Cylinders 6
Displacement 855 In³. (14 L)
Bore and Stroke 5.5 in x 6 in.

(140 mm x 152 mm)

Compression Ratio 10:1
Minimum C.C.A. at 5°C 1800
RPM

1800 rpm

1500 rpm
BHP Minimum REQ"D
at Rated kW 311 284
BMEP 160 psi 175 psi
Altitude and Ambient Temperature Requirements
The engine may be operated at the STANDBY RATING up to 3000 ft.(914m) altitude and 100°F (38°C) inlet air temperature and at the PRIME AND CONTINUOUS POWER RATING up to 5000 ft.(1524m) altitude and 100°F (38°C) inlet air temperature.  For sustained operation at high load factor at higher altitudes and temperatures, please contact IPSI.
Cooling System
High Ambient 104° F (40° C) System
Coolant Capacity with Radiator

25.5 US Gal. (97 L)

Maximum restriction on discharge side of
radiator

5 In wc (125 Pa)

1800 rpm

1500 rpm

Coolant Flow 90 GPM

82 GPM

(341 LPM)

(310 LPM)

Heat Rejection to Coolant at Rated

Full Load     13485 Btu/min

12312 Btu/min

Nat. Gas      (1423 MJ/min)

(1299 MJ/min)

Heat Rejection to Room at Rated

Full Load      1668 Btu/min

1523 Btu/min

Nat. Gas        (176 MJ/min)

(161 MJ/min)

Heat Rejection to Charge Air Cooler at Rated

Full Load       2000 Btu/min

1826 Btu/min

Nat. Gas        (211 MJ/min)

(193 MJ/min)

Air System
Maximum Air Intake
1800 rpm

1500 rpm

Restriction

15 In wc

14 In wc

(3.74 kPa)

(3.49 kPa)

Radiator Cooling Air Flow
23500 cfm

21456 cfm

(665 m³/min)

(607 m³/min)

Combustion Air Flow

477 cfm

436 cfm

(13 m³/min)

(12 m³/min)

Generator Cooling Air Flow

2348 cfm

2144 cfm

(66.4 m³/min)   (60.7 m³/min)

Exhaust System
Exhaust Manifold Outlet Size

4 in. dia. (102 cm)

Maximum Allowable Back Pressure
2 In wc (.5 kPa)
Exhaust Gas Flow at Standby Rating

1613 cfm

1473 cfm

(46 m³/min)

(42 m³/min)

Exhaust Temp at Standby Rating
1350°F

1233°F

(732°C)

(667°C)

Fuel System
Consumption at Standby Rating:
Load

1800 RPM

Natural Gas

C.F.H.(Cu.M./Hr.)

1/4 778 (22.0)
1/2 1284 (36.3)
3/4 1738 (49.2)
Full 2181 (61.7)
Load

1500 RPM

Natural Gas

C.F.H.(Cu.M./Hr.)

1/4 710 (20.1)
1/2 1172 (33.2)
3/4 1587 (44.9)
Full 1991 (56.3)
Governor Type Electronic
Governor Regulation:

+/- .25% Steady State

Generator

Model

Motor Starting KVA, 240/480 Volt WYE at
35% Voltage Dip, 100% Voltage Recovery

346 SKVA

Maximum Motor Starting KVA, 35%
Voltage Dip Oversized Generator

1380 SKVA

Reactances

480V

400V

at 105°C rise

60Hz

50Hz

Synchronous Xd

4.27

4.1

Direct Axis Transient X'd

.449

.431

Direct Axis SubtransientX"d

.274

.263

Negative Sequence X2

.286

.275

Zero Sequence Xo

.0052

.0049

Lubrication System
Engine Oil Capacity with Filters

46 qts. (43.5 L)

Oil Filter Type

Spin On

                                      

 

                             Electrical Generating Systems Association             National Fire Protection Association        